Nanchang City Enhui Medical Hygienic Materials Co., Ltd.
/
/
/
Hunan Valin Xiangtan Iron and Steel Group Co., Ltd.

  Application

Check category

Hunan Valin Xiangtan Iron and Steel Group Co., Ltd.

  • Categories:Steel
  • Author:
  • Origin:
  • Time of issue:2020-08-17 11:53
  • Views:

(Summary description)

Hunan Valin Xiangtan Iron and Steel Group Co., Ltd.

(Summary description)

  • Categories:Steel
  • Author:
  • Origin:
  • Time of issue:2020-08-17 11:53
  • Views:
Information

Customer Profile

 

Hunan Valin Xiangtan Iron and Steel Co., Ltd. (hereinafter referred to as Xiangtan Iron and Steel Co., Ltd.) was founded in 1958 and currently has 18,000 employees. After more than 50 years of construction and development, it has now formed a comprehensive production capacity of 10 million tons of steel per year. Process equipment for the entire process of coking, sintering, ironmaking, steelmaking, rolling, metal products, etc. 

Project Name

 

Water Pump Energy Saving Renovation Project of Hunan Hualing Xiangtan Iron and Steel Group Co., Ltd.

 

1.1 This technical agreement is applicable to the water pump energy-saving renovation project of the wide and heavy plate plant of Hunan Valin Xiangtan Iron and Steel Group Co., Ltd.;
1.2 The technical requirements proposed in this technical agreement are all minimum requirements, and all technical details and standards are not specified. Party B shall provide a set of high-quality equipment and installation processes that meet the requirements of this technical agreement and the listed standards And its services. The national mandatory standards concerning safety and environmental protection must be met;
1.3 If the standards used in this technical agreement conflict with the standards implemented by Party B, the higher standards will be implemented.
2 Project Overview

water station pump set name operation qty annual power savings
11water station 2# pump set (air compressor station) 2 used 2 stand by 2 34.5
3# Pump Set (High Pressure Oxygen Gun) 2 used 2 stand by 2 71.2
4# pump set (converter body) 2 used 2 stand by 2 44.4
5#Pump set (fan room) 2 for 1 2 31.2
6#Pump Group (Converter Turbidity Ring) 4 used 2 stand by 4 33.7
12water station No. 1 casting machine soft water pump set 2 for 1 2 154.4
No. 2 casting machine soft water pump set 2 for 1 2 150.4
2#Pump set (VD net ring) 2 for 1 2 31.76
4#Pump Group (VD Turbidity Ring) 3 with 1 stand by 2 32
6#Pump Group No. 2 Caster Turbidity Ring 2 for 1 2 104.4
8# pump set (hot water pump) 1 used 2 stand by 1 25.3
13water station P101 pump set 1 used 3 stand by 1 28.8
P102 pump set 2 used 2 stand by 2 44.8
P301 pump set 1 used 3 stand by 1 54.4
P302 pump set 1 used 3 stand by 1 60
total 28 sets  

 

Reconstruction content of eleven water station
(1) Net-ring high-pressure oxygen lance water supply pump set: 2 sets of customized high-efficiency environmental protection and energy-saving pumps replace the 2 water pumps currently in operation. The original matching motors will continue to be used and will not be replaced; the maximum operating conditions (main pipe) Pressure ≥1.92Mpa, flow ≥560m3/h), the system saves 758,000 kWh of electricity annually;
(2) The converter body water supply pump set: 2 sets of customized high-efficiency, environmentally-friendly and energy-saving pumps replace the 2 water pumps currently in operation. The original matching motors will continue to be used and will not be replaced; the maximum operating conditions (single furnace operation) When the pressure is ≥0.65MPa, the flow rate is ≥480m3/h, the pressure when the two furnaces are operating is ≥0.74MPa; the flow rate is ≥700m3/h); the annual electricity saving of the system is 411,000 kWh;
(3) Clean ring fan water supply pump set: 2 sets of customized high-efficiency, environmentally-friendly and energy-saving pumps replace the 2 currently running water pumps. The original matching motors will continue to be used and will not be replaced; the maximum operating conditions will be met after the transformation (main pipe pressure ≥ 0.38Mpa, flow ≥520m/h), the system saves 312,000 kWh of electricity annually;
(4) Turbid ring water supply pump unit: 4 sets of customized high-efficiency, environmentally friendly and energy-saving pumps replace the 4 water pumps currently in operation. The original supporting motors will continue to be used and will not be replaced; material: the pump unit is made of slurry pumps system

Twelve water station project content
(1) No. 1 continuous casting machine soft water pump set: 2 sets of customized high-efficiency environmental protection and energy-saving pumps replace the 2 water pumps currently in operation. The original matching motors will continue to be used and will not be replaced; the maximum operating conditions (main pipe Pressure ≥0.95Mpa, flow ≥1550m3/h), the system saves 1.42 million kWh of electricity annually:
(2) No. 2 continuous casting machine soft water pump set: 2 sets of customized high-efficiency, environmentally-friendly and energy-saving pumps replace the 2 water pumps currently in operation. The original matching motors will continue to be used and will not be replaced; the maximum operating conditions (main pipe) Pressure ≥0.95Mpa, flow ≥1550m3/h), the system saves 1.42 million kWh of electricity annually;
(3) VD clean ring water supply pump: 2 sets of customized high-efficiency environmental protection and energy-saving pumps replace the 2 water pumps currently in operation. The original matching motors will continue to be used and will not be replaced; the maximum operating conditions are met after the transformation (main pipe pressure ≥ 0.85) Mpa, flow ≥1100m3/h), the system saves 390,000 kWh of electricity annually;
(4) VD turbid ring hot water pump: 2 sets of customized high-efficiency, environmentally-friendly and energy-saving pumps replace the 3 water pumps currently in operation, replace two 4-pole 132Kw motors; install 2 low-voltage inverters, one for one type; After the transformation, it meets the maximum operating conditions (pressure ≥ 0.6 MPa, flow ≥ 1150 m3/h when a single furnace is operating), and the system saves 320,000 kWh of electricity annually;
(5) Turbid ring pump set of continuous casting machine: 2 sets of customized high-efficiency, environmentally-friendly and energy-saving pumps replace the 2 water pumps currently in operation. The original matching motors will continue to be used and will not be replaced; 2 low-voltage inverters will be installed, one tow One form; meet the maximum operating conditions after transformation (two sets of header pressure two 1.0Mpa, flow rate 2600m/h, single set pressure

Thirteen Water Station Project Content
(1) P101 water supply pump set: 1 set of customized high-efficiency, environmentally-friendly and energy-saving pumps replaces the current running water pump. The original supporting motor will continue to be used and will not be replaced; it will meet the maximum operating conditions (main pipe pressure ≥ 0.40Mpa) , Flow ≥520m3/h), and the annual electricity saving of the system is 280,000 kWh;
(2) P102 water supply pump set: 2 sets of tailor-made high-efficiency, environmentally-friendly and energy-saving pumps replace the 2 water pumps currently in operation. The original matching motors will continue to be used and will not be replaced; the maximum operating conditions are met after the transformation (main pipe pressure ≥0.52Mpa , Flow ≥ 1480m3/h), the system saves 490,000 kWh of electricity annually;
(3) P301 water supply pump set: 1 set of customized high-efficiency, environmentally-friendly and energy-saving pumps replaces the current running water pump. The original matching motor will continue to be used and will not be replaced; the maximum operating condition is met after the transformation (main pipe pressure ≥ 0.40Mpa , Flow ≥ 1450m3/h), and the annual electricity saving of the system is 384,000 kWh;
(4) P302 water supply pump set: 1 set of customized high-efficiency, environmentally friendly and energy-saving pumps replaces the current running water pump, the original matching motor will continue to be used and will not be replaced; the maximum operating condition is met after the transformation (main pipe pressure ≥ 0.95Mpa , Flow ≥680m³/h), and the annual electricity saving of the system is 664,000 kWh;

The two parties agree that the technically modified pump shall be inspected and accepted in Party B’s factory according to the following parameters. The technical design parameters are as follows:

water station pump set name operation qty pump model capacity head eff
11water station 2# pump set (air compressor station) 2 used 2 stand by 2 250S65 480 60 82%
3# Pump Set (High Pressure Oxygen Gun) 2 used 2 stand by 2 200MS63 280 195 76%
4# pump set (converter body) 2 used 2 stand by 2 200S95 300 74 80%
5#Pump set (fan room) 2 used 2 stand by 2 250S65 500 45 80%
6#Pump Group (Converter Turbidity Ring) 4 used 2 stand by 4 200MS95 300 95 78%
12water station No. 1 casting machine soft water pump set 2 used 1 stand by 2 XS200-520 750 95 80%
No. 2 casting machine soft water pump set 2 used 1 stand by 2 XS200-520 750 95 80%
2#Pump set (VD net ring) 2 used 1 stand by 2 XS125-290 500 83 82%
4#Pump Group (VD Turbidity Ring) 3 used 1 stand by 2 250MS65 580 60 80%
6#Pump Group No. 2 Caster Turbidity Ring 2 used 1 stand by 2 XS125-290 340 110 78%
8# pump set (hot water pump) 1 used 2 stand by 1 300S32 1000 20 82%
13water station P102 pump set 2 used 2 stand by 2 300S58 850 50 82%
P301 pump set 1 used 3 stand by 1 350MS44 1450 43 85%
P302 pump set 1 used 3 stand by 1 XS200-670 550 125 76%
这是描述信息
这是描述信息
这是描述信息

Add: Jiuhua Industiral Park,Xiangtan City,Hunan Province,China

这是描述信息

Call us:+86-0731-55599916
            +86-18673110460

 

Hunan M&W Pump Co., Ltd   湘ICP备14003804号-2     www.300.cn      Manager